Below we have collected answers to the questions our customers ask most often. The questions are divided into four sections: sales, technical questions, products and shipping. If you cannot find the answer to your question, contact us via the contact page — we will reply within one business day.

Sales

What does "E.T.D." in a quotation mean?

"E.T.D." (Estimated Time of Delivery) is the estimated delivery time. All our quotations are based on E.T.D. and do not include sea or air freight or carrier charges. The stated delivery period is counted in calendar days, not working days.

Why register on the StarryValve website?

StarryValve provides a full after-sales service package, especially for documentation. All customers can download order documents from the website in one click, without waiting for our working hours. In addition, some documents in the Products and Downloads sections are available only after logging into your account.

What quality certificates do we provide?

Unless otherwise agreed, we provide an EN 10204 Type 3.1 inspection certificate for all products (industrial valves) — a statement of compliance with the order, indicating the test results according to the product specification. Type 3.2 certificates are also available on request.

How to follow StarryValve news?

We regularly publish information about new products, industry news and company updates in our blog. Subscribe to our newsletter or follow the blog updates to receive the latest materials in time.

Technical Questions

What is the difference between a 5211 Mounted Pad and a 5211 Direct-Mounted Pad?

The 5211 Mounted Pad and the 5211 Direct-Mounted Pad are used to mount gear operators as well as pneumatic and electric actuators. The difference is that mounting an actuator on the standard 5211 pad requires brackets and adapters, while the 5211 Direct-Mounted Pad allows direct installation of the actuator.

Is a gate valve an isolating valve?

Yes. A gate valve is designed to operate only in the fully open or fully closed position. For throttling (regulating) the flow, globe valves and ball valves can be used. Isolating valves are used for diverting the process media, facilitating maintenance, equipment removal and pipeline shutdown.

Is stainless steel magnetic?

There is no simple yes or no answer — it depends on the specific grade. It is important to understand that stainless steel is not a pure magnetic metal but a collective name for a family of steel alloys alloyed with other metals. For example, typical stainless steel contains just over 10% chromium. Magnetic properties depend on the alloy structure: austenitic grades (304/316) are practically non-magnetic, whereas ferritic and martensitic grades exhibit magnetic properties.

Types of ball valves

There are five main construction types of ball valve bodies: one-piece, three-piece, split body, top entry and welded. The differences are determined by how the valve parts — especially the body that contains the ball — are manufactured and assembled.

What surface treatment is applied to stainless steel castings (CF8M / 1.4408)?

After sandblasting, as a finishing operation, stainless steel valves undergo pickling and ultrasonic cleaning. These procedures remove contaminants (such as iron particles and grease films) that could damage the surface or the chromium oxide layer, and promote the formation of a continuous passive chromium oxide film.

What standards does the passivation of stainless steel castings comply with?

Passivation is not part of the standard production cycle but is performed on request. The passivation procedures for stainless steel castings comply with ASTM A967-01, including the recommended Nitric 2 treatment for grade S31600 (20–45% nitric acid, minimum 30 minutes at 21–32 °C).

Does CE marking apply to DN32 valves?

When interpreting the PED 2014/68/EU directive, it is not enough to refer only to the "larger than DN32" condition — the certification scope must also be taken into account. Our valves are certified under ANNEX III, Cat. III, Module H, covering piping (mainly Tables 6, 7, 8 and partly Table 9 for DN200 and above). According to Table 7, if the product DN32 × pressure (bar) exceeds 1000, the item falls within the scope of PED/CE.

What is black oxide?

Воронение (чернение) — это конверсионное покрытие, образующееся в результате химической реакции с железом в металле и создающее защитный поверхностный слой на основе оксида железа Fe3O4.

What is the purpose of black oxide treatment?

To protect carbon steel against corrosion (rusting).

What is the standard black oxide procedure?

The standard cycle includes degreasing and cleaning, pickling, blackening and related operations. The complete procedure description is available in our technical documents — request them via the contact form.

What is the difference between trunnion mounted and floating ball valves?

The key difference is how each design achieves line sealing. In a trunnion mounted ball valve, a spring mechanism and/or line pressure presses the upstream seat against the stationary ball: the pressure acts only on a small seat surface. In a floating ball valve, line pressure presses the ball against the downstream seat, and the pressure acts on the entire upstream face of the ball, which is equal to the pipe cross-section.

Products

What is a valve?

A valve is a mechanical device that regulates the flow or pressure of the working medium. Its functions include starting and stopping the flow, regulating the flow rate, diverting the flow, preventing backflow, and controlling or relieving pressure. Structurally, a valve consists of a body with pipe connections and sealing elements operated by an actuator; positioners, sensors, pressure regulators and other devices can additionally be installed.

Types of valves by the movement of the closure member

Quarter-turn valves: the closure member with its shaft rotates 0–90° from the fully open to the fully closed position — these are fast-acting valves. Types: ball valves, butterfly valves, plug valves, spherical valves.

Multi-turn valves (linear motion): the closure member moves linearly, usually via several turns of a threaded stem. The operation is slow but provides accuracy and stability of the closure member position, which is necessary for some control valves. Types: gate valves, globe valves, needle valves, diaphragm valves.

Types of valves by function

Functional types of valves: pressure and flow rate regulation; flow shut-off when the permissible speed is exceeded (instant closure in case of pipeline failure); overpressure protection; backflow prevention (check valve); On/Off shut-off service.

What are cryogenic valves?

Cryogenic valves are designed for operation at extremely low temperatures: LNG (liquefied natural gas), LPG (liquefied petroleum gas), nitrogen and other cryogenic media.

What is an actuator?

An actuator is a device for moving and controlling a mechanism or system. It is powered by an energy source (usually electric current or pneumatic pressure) and converts it into motion: opening or closing the valve.

What is a limit switch?

A limit switch is a device used to indicate the open or closed position of a valve.

What is a solenoid valve?

A solenoid valve is a type of valve in which electric current moves a spool or cartridge consisting of a solenoid coil and tube assembly. In essence, the current shifts a pin to perform simple A/B tasks, such as opening or closing the spool.

Three-way and four-way ball valves

In three-way ball valves the ball has an L- or T-shaped bore. The T-configuration can connect any pair of ports or all three at once, but the 45° intermediate position that disconnects all three ports leaves no margin for error. The L-configuration connects the centre port to either side port, or disconnects all three, but cannot connect the side ports together. Multi-port valves with 4 or more ports are also available; the inlet is usually orthogonal to the plane of the outlets. For special tasks (for example, reversing pneumatic motors), a lever-operated four-way valve is used: its ball has two non-interconnecting L-shaped bores, sometimes called "cross" ports.

Which models hold the API 607 fire-safe certificate?

Current API 607 (6th edition) fire-safe certificates for our ball valve models are provided on request — ask our manager via the contact page.

Types of actuators

By type of motion: multi-turn, quarter-turn, linear, lever-operated.

By energy source: manual; electric (direct and alternating current); pneumatic (use compressed air or gas, widely used in industry due to their low cost, easy to diagnose and repair in the field); hydraulic.

By function: On/Off shut-off service, positioning by percentage of opening, modulation for flow control, emergency shut-down (ESD).

Other characteristics: explosion-proof design, safety integrity level (SIL), enclosure protection ratings IP and NEMA.

Shipping

HS codes for customs clearance of valves

HS codes for our valves: 848180 — ball valves, butterfly valves, gate valves, globe valves; 848130 — check valves; 848140 — safety or relief valves; 848110 — pressure-reducing valves.

Which Incoterms do you use?

The delivery standard is Incoterms 2020 terms (EXW, FOB, CIF, DAP and others — as agreed). Please clarify the preferred terms with our manager when requesting a quotation.